6AG2136-6BA01-2CA0

Confirm the exact model, specifications and quantity for your order.

Email the model, brand, quantity and destination. Attach specifications, product images or a nameplate photo.

Product Code
6AG2136-6BA01-2CA0
Dimensions
7.5 x 6.9 x 3.2 cm
Weight
0.061 Kg
Availability
In stock
Product Attachment
Download Datasheet
Request a Quote

Confirm availability, price, condition, lead time and warranty terms with your inquiry.

Ordering this product

Check the full part number and required version against your equipment. Add any electrical or connection requirements when contacting us.

Product information

SIPLUS ET 200SP F-DI 4/8×24 V DC rail based (part number 6AG2136-6BA01-2CA0) provides fail-safe digital inputs with conformal coating for the specified temperature ranges and safety integrity levels.

Detailed Parameters

Part number:6AG2136-6BA01-2CA0

Product family:SIPLUS ET 200SP

Module designation:F-DI 4/8×24 V DC

Rail based:Yes

Based on:6ES7136-6BA01-0CA0

Conformal coating:Yes

Operating temperature range:-40…+60 °C

OT2:Yes

ST1/2:Yes

OT2 short-term limit:+70 °C for 10 minutes

Fail-safe digital inputs:Yes

Safety integrity level (max):PL e (ISO 13849-1)

Safety integrity level (SIL):SIL3 (IEC 61508)

Engineering Context

SIPLUS ET 200SP F-DI rail based module (based on 6ES7136-6BA01-0CA0) provides fail-safe digital inputs.

The conformal coating is provided for the specified operating temperature range of -40…+60 °C.

Functional safety ratings are specified as PL e (ISO 13849-1) and SIL3 (IEC 61508) for the fail-safe digital inputs.

FAQ

1. What is the module designation for part number 6AG2136-6BA01-2CA0?

The module designation is SIPLUS ET 200SP F-DI 4/8×24 V DC rail based.

2. What is 6AG2136-6BA01-2CA0 based on?

It is rail based on 6ES7136-6BA01-0CA0 with conformal coating.

3. Is conformal coating included?

Yes, it is provided.

4. What operating temperature range is specified for this module?

-40…+60 °C is specified.

5. What short-term temperature limit is specified under OT2?

+70 °C for 10 minutes is specified.

6. What functional safety levels are specified for the fail-safe digital inputs?

PL e (ISO 13849-1) and SIL3 (IEC 61508) are specified.