SIPLUS G120 PM240-2 (part number 6AG1210-1PE23-2UL0) is designed as an IP20, unfiltered drive power module with integrated braking chopper for 380-480 V 3 AC systems.
Detailed Parameters
Based on:6SL3210-1PE23-3UL0
Degree of protection:IP20
Conformal coating:with conformal coating
Design:FSC
Integrated braking chopper:yes
Filtering:unfiltered
Supply voltage:380-480 V 3 AC
Supply voltage tolerance:+10/-10%
Line frequency:47-63 Hz
Operating temperature range:-20…+50 °C
Power high overload:11 kW at 200% 3 s, 150% 57 s, 100% 240 s
Power low overload:15 kW at 150% 3 s, 110% 57 s, 100% 240 s
Dimensions (HxWxD):355x 140x 165
Operating unit released:without CU and operating unit released as of CU FW version V4.7 HF8
Engineering Context
The product is SIPLUS G120 PM240-2 based on 6SL3210-1PE23-3UL0 with conformal coating.
The integrated braking chopper is provided for the specified 380-480 V 3 AC supply range (47-63 Hz).
High and low overload power levels are specified for the module under the given 200%/150%/100% and 150%/110%/100% load-time combinations.
FAQ
1. What is the product family and module designation for 6AG1210-1PE23-2UL0?
SIPLUS G120 PM240-2.
2. Is an integrated braking chopper included in 6AG1210-1PE23-2UL0?
Yes, it is specified with integrated braking chopper.
3. What supply voltage and line frequency range is specified for 6AG1210-1PE23-2UL0?
380-480 V 3 AC (+10/-10%) and 47-63 Hz.
4. What degree of protection and filtering type are specified?
Degree of protection IP20 and specified as unfiltered.
5. What operating temperature range is specified?
-20…+50 °C.
6. What overload power values are specified for high overload and low overload?
High overload: 11 kW at 200% 3 s, 150% 57 s, 100% 240 s; Low overload: 15 kW at 150% 3 s, 110% 57 s, 100% 240 s.
7. Are there notes about the operating unit release and CU FW version?
Operating unit is released without CU as of CU FW version V4.7 HF8.